Shipping from as low as 8,00€

Customer care
  • FINGER BRACE Size 2 Dr. GIBAUD® ORTHO -18%

FINGER BRACE Size 2 Dr. GIBAUD® ORTHO

22.58€ 27.50€
  • Purchase 3 items for 22.13€ each
  • Purchase 4 items for 21.68€ each
  • Purchase 5 items for 21.23€ each
Price information ⓘ

FINGERS BRACE Size 2 Dr. GIBAUD® ORTHO - Medical Device

Trauma to the long fingers of the hand that can benefit from immobilization, such as:

sprains
strains
dislocations
compound fractures

Main function of the Medical Device

The medical device provides immobilization and effective treatment of long finger injuries of the hand.

Characteristics

Finger-wrist splint, moldable to keep the metacarpophalangeal and proximal interphalangeal joints in flexion

Usable in palmar or dorsal position

Fixed distal and proximal straps and two repositionable intermediate straps

Textile Composition

100% polyamide

100% aluminum cue

How to wear it

Open the four straps. Place the injured finger on the splint together with the longer neighboring finger. Close the strap at the finger and wrist ends. Tighten the mid straps, one around the fingers and the other around the hand. These two straps can be repositioned along the hook and loop fasteners.

Unless otherwise prescribed, it is recommended to shape the splint to obtain a flexion of the metacarpophalangeal joint of 60 ° -70 °, the proximal inter-phalangeal one of 10 ° -20 ° and the distal inter-phalangeal one in extension.

Warnings and precautions for use

Store in a dry environment away from excessive heat and light.

Do not prolong the use of the product without medical advice.

The product is designed for use by one person only, do not use it on multiple people.

The product must not be used in direct contact with damaged skin.

When adjusting the straps, tighten them so that they are stable but comfortable.

The brace should not be used if relative, absolute immobilization or surgery is required.

If you encounter problems in using the product such as the appearance of pain or obvious local signs, remove it and contact a healthcare professional.

In the event of a serious accident following the use of the product, contact the manufacturer and the local health care provider.

It is advisable, the first time, to have the product positioned by a qualified operator and to carry out subsequent positioning independently in the same way.

Washing instructions

Hand wash in warm water with neutral soap or detergent, rinse well, wring gently, let dry horizontally. Do not bleach, do not tumble dry, do not iron, do not dry clean.

Instructions for disposal

The product must be disposed of in compliance with current regulations.

CASE: C / PAP 81 - PAPER

Recycling.

Check the provisions of your municipality.