Shipping from as low as 8,00€

Customer care
  • SOFARMAPIU' SELFTEST VIT D -37%

SOFARMAPIU' SELFTEST VIT D

6.19€ 9.90€
  • Brand: SO.FARMA.MORRA SpA
  • Product Code: 986885390
  • EAN: 8054320670209
  • Availability: In Stock
  • Purchase 3 items for 6.07€ each
  • Purchase 4 items for 5.94€ each
  • Purchase 5 items for 5.82€ each
Price information ⓘ

SoFarma

VITAMIN D TEST

Description
Rapid immunochromatographic test for the semi-quantitative detection of 25-hydroxyvitamin-D in human fingerstick blood.
This test can provide a preliminary diagnostic result and can be used in screening for vitamin D deficiencies.
Immunological test based on the principle of competitive binding. During the test, the mixture migrates up the membrane chromatographically by capillary action. The membrane is pre-coated with 25(OH)D antigens on the test line(T) area of ​​the test strip. During the test, the 25 (OH) D present in the sample will compete with the 25 (OH) D present on the test line (T) due to the limited amount of anti-25 OH vitamin D antibodies present in the conjugate. The higher the concentration of the 25(OH)D in the sample, the lighter the T line will be.
The result can be interpreted according to the color card supplied with this kit.
With the procedural control function, a colored line will always appear in the control line area (C) to indicate that a sufficient volume of sample has been added and the membrane has been soaked.

Instructions for use
Wash your hands with soap and rinse with clean warm water.
Bring the package to room temperature before opening it. Open the package, remove the test and place it on a clean, flat surface. Perform the test within one hour of opening, best results will be obtained by testing immediately after opening the foil package.
Remove the dropper, swab vial, sterile lancet and alcohol wipe, placing them near the test.
Gently pull to remove the lancet protective cap. Use the alcohol wipe to clean the fingertip of the middle or ring finger, where the puncture will be performed. Wait until the affected area is dry again. Press the lancet on the side where the cap was removed; the tip retracts automatically and safely after use.
Massage your hand towards the tip of the middle or ring finger that has been stung (without touching the sting site) to obtain a drop of blood.
Bring the capillary dropper into contact with the blood, without pressing the bulb. The blood will migrate into the capillary dropper until it reaches the line indicated on the dropper. You can massage your finger again to get more blood if the fill line has not been reached. As far as possible, try to avoid the formation of air bubbles.
Pour the collected blood into the sample well (S) on the device by pressing the dropper bulb.
Wait until the blood is completely poured into the well. Unscrew the buffer vial cap and add 2 drops of buffer to the buffer well (B) on the device and start the timer.
Wait for the colored line(s) to appear. Read the results at 10 minutes. Compare the intensity of the T line with the “Vitamin D Color Card” provided inside the kit to interpret the level of vitamin D in the blood. Do not interpret the result after 20 minutes.

Reading the results
0-25 25-75 75-250
25-OHVitamin D level Reference range (ng/mL) Reference range(mcmol/L)
Deficient 0-10
Insufficient 10-30
Sufficient 30-100

-