T-PLUS Infrared Thermometer CA-MI - Medical Device

Medical Device Class IIA (Directive 93/42 / EEC).
Conical stepped design: captures and concentrates infrared rays improving the measurement. Prevents errors caused by incorrect positioning. Indicates to the user when the placement is correct.
It minimizes the systematic errors caused by the variation in ambient temperature.
Visual and sound fever notification: triple backlight and 3 different buzzers to indicate different temperatures.
Measurements in 1 second.
It detects the body temperature, and that of the surfaces.

  • Terms of use
    • - Temperature: 15 ° C-40 ° C
    • - Humidity: 15% -93% RH
    • - Pressure: 70-106 kPa
  • Power supply: 2 x 1.5V AAA alkaline battery
  • Automatic shutdown: 30 seconds
  • Measurement range
    • - Body temperature mode: 32 ° C-43 ° C (89.6 ° F-109.4 ° F)
    • - Object temperature mode: 0 ° C-100 ° C (32 ° F-212 ° F)
  • Minimum unit used: 0.1 ° C / 0.1 ° F
  • Accuracy
    • - ± 0.2 ° C, in the range between 35 ° C-42 ° C
    • - ± 0.3 ° C, outside this range

How to use

Body temperature measurement
1. Press the power button to turn on the product and start the front temperature measurement.
2. Aim the sensor at the center of the forehead at a distance less than or equal to 3 cm.
3. Press the button to take instant measurement.
If the distance is greater than 3 cm, the product does not measure the temperature and a flashing error message appears on the screen inviting you to approach the thermometer (progressively). Then bring the thermometer to the right distance and the measurement will be completed.
When the measurement is done, a warning tone sounds and the measurement result appears on the screen.
Continuous measurements cannot be made at intervals of less than 5 seconds.

Surface temperature measurement
In ON mode / When the product is on, press the power button for 3 seconds: the thermometer will enter object temperature mode and the “mod. object temperature ". In this mode it is possible to measure the ambient or object temperature. To maintain measurement accuracy, do not use the product for frontal measurements in this mode.
Regardless of the mode the device is in before it is turned off, the default setting when it is turned on again is always the front one.

Cleaning
- Probe: if there is dust or dirt on the sensor or groove, clean with a cotton swab dipped in denatured alcohol. (Attention: do not place the product under a stream of water to wash it).
- Body: clean the product by wiping with a clean, dry cloth to avoid scratches. (Caution: Do not clean the product body with water). Attention: due to the particularly sensitive technology in place in detecting the infrared temperature, residues of dust and dirt can not only affect the accuracy of the measurement, but also cause bacterial infections. It is advisable to carefully clean the product after each use. as indicated above.

Warnings

Attention: due to the particularly sensitive technology in place in infrared temperature detection, dust and dirt residues can not only affect the accuracy of the measurement, but also cause bacterial infections. It is recommended to carefully clean the product after each use, as indicated above. Warnings
Check the product before each use. Do not use the product if it is damaged. Using the damaged product can cause injury, incorrect results, or serious damage. Avoid placing the product near fire or heat sources which could cause the batteries to explode. If problems arise with the product, during installation, maintenance or use, contact the Manufacturer and / or Distributor assistance. Do not open or repair the product by yourself. Please contact the Manufacturer and / or Distributor in case of anomalous situations.
The infrared thermometer has been tested and found to comply with standards for electromagnetic disturbances (EMC) for healthcare products. These limits are designed to provide reasonable protection against harmful interference in a typical medical installation. Do not use the product in conjunction with other devices with a high level of electromagnetic emission. The product is to be used for the sole purpose of measuring body temperature. It cannot be used for diagnostic purposes or for continuous measurements in surgical operations. The product cannot be used for self-diagnosis and therapy: follow the doctor's instructions. The main material of the product body is plastic. Beware of potential allergic reactions to the material. Do not use on infected wounds. Do not touch the infrared sensor and do not blow on it with your mouth. Ask doctors and / or specialized medical personnel how to interpret the results of measurements made with this device. Do not use cell phones near the product. Do not use equipment that generates electromagnetic fields near the product. The use of heating or cooling devices, such as thermal blankets or pillows, or ice packs, can alter the proper functioning of the product and pose an additional risk to the patient. Do not store the product in direct sunlight, in hot, humid or dusty environments. The performance and proper functioning of the product could be affected. Do not disassemble or repair the product yourself (including spare parts). Do not clean or carry out maintenance operations during use. Wait 30 minutes before use if there is a sudden change in the environment (e.g. moving from an area with direct sunlight to an area with air conditioning), or the accuracy of the device may be affected / altered. Deteriorated sensors and electrodes, as well as loose electrodes, can affect device performance and cause various other problems. Do not open the battery compartment near any potential ignition source which could ignite the batteries and cause a fire. Remove the batteries if they are not used for long periods. Keep the product out of the reach of infants, children and pets. Ingestion and / or inhalation of the small parts contained in the device is dangerous and could even be fatal. The patient is intended as an operator. Under normal circumstances the patient can measure and change the battery and maintain the device and its accessories as described in the user manual. Children should not use the product. Children up to the age of twelve may only use the device under adult supervision. Children under the age of 12 and / or people with disabilities who limit their ability to understand and use products like this, must not have access to the device and can only use it under the supervision of an adult with full mental faculties. Do not subject the device to forces to bend, compress or twist the device. Do not drop the product or subject it to strong impact. Do not subject the product to sudden and large thermal changes. The performance of the product could be altered by the following causes: use or storage outside the recommended temperature and humidity; patient temperature lower than ambient temperature. If the device has been stored in sub-zero temperatures, naturally warm it to room temperature before using it. Clean the sensor before storing the product.

storage

Store at a temperature between -25 ° C and + 60 ° C, with relative humidity <90% RH and atmospheric pressure between 70 kPa and 106 kPa.
Validity for intact packaging: 60 months.

Format

Pack of 1 device.