Shipping from as low as 8,00€

Customer care
  • WELLION LEONARDO GLU-KET YELLOW -15%

WELLION LEONARDO GLU-KET YELLOW

44.53€ 52.39€
  • Purchase 3 items for 43.64€ each
  • Purchase 4 items for 42.75€ each
  • Purchase 5 items for 41.86€ each
Price information ⓘ

wellion GALILEO GLU / KET Yellow - Medical Device

Medical device for in vitro diagnostic use for self-monitoring.
Blood Glucose and Ketone Monitoring System to help you easily monitor blood glucose and ketone levels for safe prevention of diabetic ketoacidosis.
The system does not require you to manually code the meter in order to significantly reduce test errors.
At high glucose levels it is of utmost importance to test for ketones.
Glucose is the main source of energy for the body, but it can only be metabolized with a sufficient level of insulin, otherwise the body uses fatty acids as an alternative source of energy, thus forming high levels of ketones in the blood.
Non sterile product.

Functionality

Warning signs for hypoglycemia and hyperglycemia; pre and post meal marker; exercise marker; marker of drug intake and insulin therapy.
Thresholds for blood glucose can be set to understand blood sugar levels and blood glucose status.

Intended use

The product is intended for the quantitative measurement of glucose in fresh capillary whole blood from fingertip, palm, forearm.
For cholesterol in internal capillary blood from fingertips.
Alternative test sites for glucose testing can only be considered during a stabilized situation (when glucose does not change rapidly). Test measurements are external to the body (in vitro diagnostic use).
The product is intended for self-testing by people with diabetes or by healthcare professionals in clinical settings as an aid to monitor blood sugar and cholesterol levels in diabetes mellitus. It is not indicated for diagnosis or screening of diabetes or for neonatal use.
Severe dehydration can lead to inaccurate blood glucose test results.
A hematocrit range that is greater than 70% or less than 20% can cause inaccurate blood glucose test results.
A hematocrit range that is greater than 60% or less than 20% can cause inaccurate ketone test results.

Content

Wellion tool (batteries included).

How to use

Read the user guide carefully.

Warnings

Medication intake:
Do not alter or discontinue any medication intake if the test result is positive, consult your doctor or healthcare professional instead.
Alternative test sites:
Consult your physician to decide if an AST can be performed.

storage

Keep away from sources of light and heat.
Store at a temperature between -20 ° C and + 50 ° C.

Format

Available in 3 colors: white, yellow and black.
Net weight: 67 g.

Cod. WELL1000KW / WELL1000KY / WELL1000KB